Adapter joiner Double Socket Manufacturer,Supplier and Exporter in India
Product Code : SCL-GW-11987
The Adapter Joiner Double Socket by Scientifc Equipment is a high-quality laboratory glassware connector designed to join compatible cone-joint glassware components in a secure and stable manner. It is commonly used in chemistry laboratories, research centers, educational institutions, and industrial testing labs where reliable glassware connection is required.
Manufactured from durable borosilicate glass, this double socket adapter offers excellent clarity, strength, and resistance to normal laboratory conditions. Its double socket design allows users to connect two compatible cone joints, making it useful for distillation setups, reflux arrangements, filtration systems, gas-transfer assemblies, and general laboratory glassware configurations.
Scientifc Equipment focuses on practical laboratory solutions that support safe handling, accurate fitting, and dependable performance. This Adapter Joiner Double Socket is suitable for students, researchers, lab technicians, and professionals who need reliable glassware connections during experiments and routine lab procedures.
Key Features
- Double socket design for connecting compatible cone-joint glassware
- Made from durable borosilicate glass
- Clear glass body for easy visual inspection
- Suitable for laboratory glassware assemblies
- Provides secure and stable fitting when used with matching joints
- Autoclavable and reusable with proper care
- Useful for distillation, reflux, filtration, and gas-transfer setups
- Easy to clean, install, and store
- Suitable for school, college, research, and industrial laboratories
Product Specifications
|
Specification |
Details |
|
Product Name |
Adapter Joiner Double Socket |
|
Brand |
Scientifc Equipment |
|
Material |
Borosilicate Glass 3.3 |
|
Joint Type |
Double Socket |
|
Design |
Straight glass adapter joiner |
|
Available Socket Sizes |
Common sizes include 14/23, 19/26, 24/29, 29/32, or as per requirement |
|
Example Variant |
14/23 double socket |
|
Approx. Tube OD |
Around 18 mm for selected variants |
|
Approx. Total Length |
Around 135 mm for selected variants |
|
Autoclavable |
Yes |
|
Reusability |
Reusable with proper cleaning and handling |
|
Application |
Laboratory glassware connection |
|
Suitable For |
Chemistry labs, research labs, school labs, college labs, and testing laboratories |
How to Use Adapter Joiner Double Socket
- Select the correct double socket size according to the cone joints of the glassware.
- Inspect the adapter for cracks, chips, or visible damage before use.
- Clean and dry the adapter and the glassware joints before assembly.
- Insert the first compatible cone joint into one socket of the adapter.
- Insert the second compatible cone joint into the other socket.
- Ensure both joints are properly seated and aligned.
- Use joint clips, clamps, or stands if extra stability is required.
- Carry out the experiment according to standard laboratory safety procedures.
- After use, allow the adapter to cool if it has been exposed to heat.
- Clean, dry, and store the adapter safely in a laboratory glassware cabinet.
Safety and Maintenance Tips
- Handle carefully to avoid glass breakage.
- Do not use if the adapter is cracked, chipped, or damaged.
- Use only with compatible cone-joint glassware.
- Avoid sudden temperature changes to reduce thermal shock risk.
- Do not force mismatched joints together.
- Use clamps or joint clips for vertical or pressurized setups.
- Clean properly after use to prevent contamination.
- Store in a safe, padded, or organized glassware storage area.
- Always wear suitable laboratory safety gear, including safety glasses and gloves.
Applications
The Adapter Joiner Double Socket by Scientifc Equipment is suitable for:
- Laboratory glassware connections
- Distillation assemblies
- Reflux systems
- Filtration arrangements
- Gas-transfer setups
- Vacuum-line arrangements, when compatible
- Chemistry practicals
- Research experiments
- Educational laboratory demonstrations
- General scientific glassware assembly
Why Choose Scientifc Equipment Adapter Joiner Double Socket?
Scientifc Equipment provides dependable laboratory accessories designed for safe handling, accurate fitting, and practical laboratory use. The Adapter Joiner Double Socket is built for smooth glassware connection and repeated use in educational, research, and industrial laboratory environments.
Expert Use Note
For best performance, always match the socket size with the cone size of the connected glassware. Using the wrong joint size may cause leakage, instability, glass damage, or unsafe laboratory operation.
FAQ
- What is an Adapter Joiner Double Socket used for?
It is used to connect two compatible cone-joint glassware components in laboratory setups.
- What is the material of this adapter?
The Adapter Joiner Double Socket is made from borosilicate glass, which is commonly used for laboratory glassware.
- Is this adapter reusable?
Yes, it is reusable if cleaned properly and handled with care.
- Is the Adapter Joiner Double Socket autoclavable?
Yes, borosilicate glass double socket adapters are generally autoclavable.
- Which sizes are available?
Common socket sizes include 14/23, 19/26, 24/29, and 29/32. Availability may vary by model or requirement.
- Can it be used in distillation setups?
Yes, it can be used in compatible distillation, reflux, filtration, and other glassware assemblies.
- How should I clean the adapter?
Clean it with a suitable laboratory cleaning solution, rinse with distilled water, and dry it properly before storage.
- Is it suitable for school and college laboratories?
Yes, it is suitable for school laboratories, college laboratories, research centers, and general laboratory use.
SEO Keywords